Technical specification for low smoke halogen free flame retardant tape
1. Scope of application
Low smoke halogen-free flame retardant tape is made of glass fiber tape impregnated with flame-retardant adhesive without any halogen. It has high flame retardant property after curing. It is suitable for all kinds of low smoke halogen-free flame retardant cable, fire-resistant cable core and cable wrapping.
2. Technical conditions
2.1 appearance requirements
The burning band is a white double-sided dipping flat sheet, and the surface should be smooth and smooth without wrinkles and other mechanical impurities; The edges of both ends of each roll should be flat and clean without cracks.
2.2 dimensions and tolerances
See Table 1.
Table 1 dimensional requirements of low smoke halogen free flame retardant tape
Width and tolerance mm | Thickness and tolerance mm | Inner hole of each roll mm | Outer diameter of each coil mm |
15~40±1.5 45~80±2.0 | 2+0.03-0.01 | 80±2 | 280~350 |
Note: it must be tightly and neatly wound on the shaft core with specified inner diameter, without looseness and joint.
2.3 main technical performance
See Table 2.
Table 2 main properties of low smoke halogen free flame retardant tape
Serial number | name | performance requirement | |
one | Oxygen index% not less than | fifty-five | |
two | Temperature index ℃ not less than | four hundred | |
three | Smoke density DM (NF method) is not greater than | one hundred and fifty | |
four | Corrosive gases are released during combustion | Conductivity μ S / mm not greater than | ten |
PH value not less than | four point three | ||
five | Radial tensile strength n / 25 × 100 mm, not less than | four hundred and forty | |
six | Weight per unit area g / M two No more than | two hundred and ten |
3 test items, test methods and test types
See Table 3.
Table 3 inspection items of low smoke halogen free flame retardant tape
Test items | test method | Type of test |
appearance | Visual inspection | S |
size | Vernier caliper, micrometer | S |
Oxygen index | GB/T2406-93 | S |
Radial breaking strength | GB/T1040-92 | S |
Weight per unit area | balance | S |
4 inspection rules
4.1 inspection methods and requirements
4.1.1 conduct random inspection at least once every 2 tons.
4.1.2 sampling method
Take 2 or more samples for each specification.
4.1.3 each batch of low smoke halogen-free flame retardant tape shall be attached with the quality assurance certificate or test report of the supplier's materials.
4.2 test items
4.2.1 the inspection items include appearance, width and thickness of LSZH flame retardant tape.
4.2.2 other performance shall be accepted according to the manufacturer's warranty or test report.
5 packaging, transportation and storage
5.1 packaging
The low smoke and halogen-free flame retardant tape shall be packed in paper or plastic bags, and the package shall be intact without damage; There should be a label on the outside of the package, which should indicate the name of the manufacturer, date of manufacture, net weight and certificate of conformity.
5.2 transportation
It is not allowed to throw it down from high place and not be exposed to rain.
5.3 storage
In a clean, dry and ventilated warehouse.