Technical Specification for water blocking tape for cable and optical cable
1 Scope
This specification specifies the classification, requirements, test methods, inspection rules, marking, packaging, transportation and storage of waterproof tape materials for cables and optical cables (hereinafter referred to as water blocking tapes).
2 relevant standards
2.1 Executive Standards
Water blocking tape for cables and optical cables JB / t10259-2001
2.2 reference standards
GB / t450 paper and board - taking of test specimens
GB / t462 paper and board Determination of moisture
GB / t60003 determination of mass per unit area of Nonwovens
FZ / t60004 determination of thickness of Nonwovens
3 product classification
The product classification meets the requirements of Table 1.
Table 1 representation of waterstop
Product category | Product model | Product name | Specifications |
Non conductive resistance hose | ZDD | Single side water stop | Nominal thickness × Width mm |
ZDS | Double water stop | ||
ZDF | Membrane water barrier | ||
Semi conductive resistance hose | ZDBD | Semi conductive single side water blocking tape | |
ZDBS | Semi conductive double-sided waterstop |
4 technical requirements
4.1 appearance
The water blocking Belt should have uniform fiber distribution, smooth surface, no wrinkles, creases and abrasion, no crack, no delamination, no powder material falling off at the width edge. After being coiled, it should be tightly wound and the disk surface should be smooth.
4.2 thickness, unit weight, expansion rate and expansion height
See Table 2.
Table 2 specifications and water resistance of water blocking tape
Product classification | model | Nominal thickness and tolerance mm | Unit weight and tolerance g/m two | Expansion rate mm/min | Expansion height mm |
wrong guide electric Hindrance water belt
Non conductive waterstop | ZDD | 0.20±0.03 | 70±7 | ≥8 | ≥12 |
0.25±0.03 | 80±8 | ≥10 | ≥14 | ||
0.30±0.03 | 90±9 | ≥12 | ≥16 | ||
ZDS | 0.20±0.03 | 80±8 | ≥8 | ≥12 | |
0.25±0.03 | 90±9 | ≥10 | ≥14 | ||
0.30±0.03 | 100±10 | ≥12 | ≥16 | ||
0.40±0.03 | 120±10 | ≥14 | ≥18 | ||
0.50±0.03 | 140±12 | ≥16 | ≥20 | ||
ZDF | 0.20±0.03 | 90±9 | ≥8 | ≥12 | |
0.25±0.03 | 100±10 | ≥10 | ≥14 | ||
0.30±0.03 | 110±10 | ≥12 | ≥16 | ||
0.40±0.03 | 130±10 | ≥14 | ≥18 | ||
half guide electric Hindrance water belt | ZDBD | 0.30±0.03 | 130±10 | ≥10 | ≥14 |
0.40±0.03 | 150±12 | ≥12 | ≥16 | ||
0.50±0.03 | 170±12 | ≥14 | ≥18 | ||
0.60±0.03 | 190±12 | ≥16 | ≥20 | ||
ZDBS | 0.30±0.03 | 130±10 | ≥10 | ≥14 | |
0.40±0.03 | 150±12 | ≥12 | ≥16 | ||
0.50±0.03 | 170±12 | ≥14 | ≥18 | ||
0.60±0.03 | 190±12 | ≥16 | ≥20 |
4.3 width and length
The width and length of water stop belt shall meet the requirements in Table 3.
Table 3 requirements for width and length of waterstop
Width and tolerance mm | Coil length and tolerance M |
Required width ± 0.3 | Delivery reel length + 20 0 |
4.4 other properties
Other performances of the water stop belt meet the requirements of Table 4.
Table 4 physical and chemical properties of waterstop
Serial number | Items | Company | Technical index | |||
Non conductive resistance hose | Semi conductive resistance hose | |||||
one | breaking strength * ) | N/cm | ≥40 | ≥40 | ||
two | Longitudinal elongation at break | % | ≥12 | ≥12 | ||
three | thermal stability | Long term temperature resistance (90 ℃, 24h) | Expansion height | mm | ≮ initial value | ≮ initial value |
Instantaneous temperature resistance (230 ℃, 20s) | ≮ initial value | ≮ initial value | ||||
four | Hydrogen evolution value (80 ℃, 24h) | μ l/g | ≤0.05 | — | ||
five | acid value | mgKOH/g | ≤1.0 | — | ||
six | Moisture content | % | ≤7 | ≤7 | ||
seven | Surface resistance | Ω | — | ≤1500 | ||
eight | Volume resistivity | Ω·cm | — | ≤1 × ten five | ||
*The performance index can also be determined by negotiation between the supplier and the demander according to different process. |
4.5 joint requirements of waterstop
There should be no joint for the water stop belt with coil length of 500m and below, and one joint is allowed when it is more than 500m. The thickness of the joint shall not exceed 1.5 times of the original thickness, and the breaking strength shall not be less than 80% of the original index. The performance of adhesive tape for joint shall be consistent with that of base material of waterstop, and shall be clearly marked.
5 test method
The test method is in accordance with table 5.
Table 5 related test of water stop belt
Serial number | Test items | Test conditions | requirement | test method |
one | appearance | It is in accordance with 6 test methods in JB / t10259-2008 | Comply with 4.1 | Visual inspection |
two | thickness | In accordance with table 2 | FZ/T60004 | |
three | ration | In accordance with table 2 | FZ/T60003 | |
four | Width, length | In accordance with table 3 | ||
five | Expansion rate and height | In accordance with table 2 | Appendix A of JB / t10259-2008 | |
six | Thermal stability test | In accordance with table 4 | Article 6.7 in JB / t10259-2008 | |
seven | breaking strength elongation at break | In accordance with table 4 | FZ/T60005 | |
eight | Moisture content | In accordance with table 4 | GB/T462 | |
nine | Hydrogen evolution value | In accordance with table 4 | Appendix B of JB / t10259-2008 | |
ten | acid value | In accordance with table 4 | GB/T4945 | |
eleven | Surface resistance | In accordance with table 4 | Appendix C of JB / t10259-2008 | |
twelve | Volume resistivity | In accordance with table 4 | Appendix D of JB / t10259-2008 |
6 inspection rules
6.1 inspection methods and requirements
6.1.1 the water stop belts produced by qualified suppliers (returned without quality problems within one year) shall be sampled and inspected at intervals.
6.1.2 the water stoppers supplied by the new manufacturer shall be inspected in each batch, and those qualified in five consecutive sampling shall be transferred to sampling inspection in alternate batches.
6.1.3 if the water stop belt of the designated manufacturer is inspected once, if it is unqualified, it shall be inspected according to the provisions of the supply materials.
6.1.4 for each batch of water stoppers, the quality assurance certificate or test report of the supplier's materials shall be attached.
6.1.5 sampling method: take 2 rolls or more for each specification.
6.2 test items
6.2.1 the inspection items are thickness, tensile strength and elongation at break.
6.2.2 the performance that cannot be tested shall be accepted according to the manufacturer's test report or warranty.
7 packing
The products shall be packed in trays with one plastic bag for each plate, and several plates shall be packed in large plastic bags, and then cartons with suitable diameter of water blocking belt shall be provided with product quality certificate.
8 mark
Each plate of product shall be marked with product name, code, specification, net weight, plate length, product batch number, date of manufacture, standard number and factory name, etc., as well as other marks such as "moisture proof and heat proof".
9 annex
The water blocking belt shall be attached with product certificate and quality assurance certificate when delivery.
10 transportation
The product should avoid moisture and mechanical damage, keep clean, dry, free from pollution, and complete packaging.
11 storage
It should be stored in a dry, clean and ventilated warehouse away from direct sunlight. The storage period is 12 months from the date of manufacture. If the time limit is exceeded, it should be inspected again according to the standard. After passing the inspection, it can still be used.