Computer signal cable
- Tel:+86-0550-7516689
- Fax:0550-7513058
- Mail:ahhl@ahhonglin.com
Description
DJYPV | PE insulated twisted pair copper wire braided separately shielded PVC protection Computer cable sleeve meter | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYVP | PE insulated twisted pair copper wire braided total Shielding PVC protection Computer cable sleeve meter | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYPVP | Separate shielding and total shielding of PE insulated twisted pair copper wire Vinyl chloride sheathed computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYP2V | PE insulated twisted pair copper tape sub shielded PVC sheath meter Computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYVP2 | Polyethylene insulated twisted pair copper tape total Shielding PVC sheath meter Computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYP2VP2 | Polyethylene insulated twisted pair copper tape partial shielding and total shielding poly (vinyl chloride) Olefin sheathed computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYP3V | Polyethylene insulated twisted pair aluminum plastic composite tape with separate Shielding PVC Sheathed computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYVP3 | Polyethylene insulated twisted pair aluminum plastic composite tape total Shielding PVC Sheathed computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYP3VP3 | Separate shielding and total shielding of PE insulated twisted aluminum plastic composite tape PVC sheathed computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYPVR | PE insulated twisted pair copper wire braided separately shielded PVC protection Computer cable sleeve | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYVPR | PE insulated twisted pair copper wire braided total Shielding PVC protection Computer cable sleeve | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYPVPR | Separate shielding and total shielding of PE insulated twisted pair copper wire Vinyl chloride sheathed soft computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYP2VR | PE insulated twisted pair copper tape with separate Shielding PVC sheath Computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYVP2R | PE insulated twisted pair copper tape total Shielding PVC sheath soft Computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYP2VP2R | Polyethylene insulated twisted pair copper tape partial shielding and total shielding poly (vinyl chloride) E-sheathed soft computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYP3VR | Polyethylene insulated twisted pair aluminum plastic composite tape with separate Shielding PVC Sheathed soft computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYVP3R | Polyethylene insulated twisted pair aluminum plastic composite tape total Shielding PVC Sheathed soft computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYP3VP3R | Separate shielding and total shielding of PE insulated twisted aluminum plastic composite tape PVC sheathed soft computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline occasion |
DJYPV22 | PE insulated twisted pair copper wire braided separately shielded PVC protection Armored computer cable with steel belt | Electrostatic shielding is required for laying indoor, cable trench and pipeline Large mechanical external force fixed field combined bearing |
DJYVP22 | PE insulated twisted pair copper wire braided total Shielding PVC protection Armored computer cable with steel belt | Electrostatic shielding is required for laying indoor, cable trench and pipeline Large mechanical external force fixed field combined bearing |
DJYPVP22 | Separate shielding and total shielding of PE insulated twisted pair copper wire Vinyl chloride sheathed steel tape armored computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline Large mechanical external force fixed field combined bearing |
DJYP2V22 | PE insulated twisted pair copper tape with separate Shielding PVC sheathed steel Install computer cable armor | Electrostatic shielding is required for laying indoor, cable trench and pipeline Large mechanical external force fixed field combined bearing |
DJYVP2-22 | PE insulated twisted pair copper tape total Shielding PVC sheathed steel Install computer cable armor | Electrostatic shielding is required for laying indoor, cable trench and pipeline Large mechanical external force fixed field combined bearing |
DJYP2VP2-22 | Polyethylene insulated twisted pair copper tape partial shielding and total shielding poly (vinyl chloride) Computer cable with olefin sheath and steel strip armour | Electrostatic shielding is required for laying indoor, cable trench and pipeline Large mechanical external force fixed field combined bearing |
DJYP3V22 | Polyethylene insulated twisted pair aluminum plastic composite tape with separate Shielding PVC Computer cable with sheathed steel strip armour | Electrostatic shielding is required for laying indoor, cable trench and pipeline Large mechanical external force fixed field combined bearing |
DJYVP3-22 | Polyethylene insulated twisted pair aluminum plastic composite tape total Shielding PVC Computer cable with sheathed steel strip armour | Electrostatic shielding is required for laying indoor, cable trench and pipeline Large mechanical external force fixed field combined bearing |
DJYP3VP3-22 | Separate shielding and total shielding of PE insulated twisted aluminum plastic composite tape PVC sheathed steel tape armored computer cable | Electrostatic shielding is required for laying indoor, cable trench and pipeline Large mechanical external force fixed field combined bearing |
