PVC insulated power cable
- Tel:+86-0550-7516689
- Fax:0550-7513058
- Mail:ahhl@ahhonglin.com
Description
Purpose:
This product is mainly used for 0.6/1kv power transmission and distribution. When flame retardant is required, flame retardant model can be selected. The fire-resistant type can be used in high-rise buildings, large shopping malls and other high-density areas that need fire-fighting and life-saving.
Executive standard:
This product is in accordance with GB 12706 1、GB12706. 2. Design and manufacture.
Flame retardant PVC insulated power cables and fire-resistant PVC insulated power cables are manufactured according to the enterprise standards, among which the flame retardant specially conforms to GB 12666 5 (iec332-3) and fire resistance characteristics of composite GB 12666.6 (iec331).
Model code list
project | Code name | meaning |
Flame retardant properties | - | Non flame retardant (omitted) |
ZR | Flame retardant* | |
NH | Fire resistant cable | |
insulation | V | PVC insulation |
conductor | - | Copper conductor (omitted) |
L | Aluminum conductor | |
Sheath or inner sheath | V | polyvinyl chloride |
VD | Low smoke and low halogen flame retardant PVC | |
Y | polyethylene | |
E | Flame retardant polyolefin | |
Armor layer | two | Double layer steel strip armor |
three | Fine steel wire armour | |
four | Thick steel wire armor | |
Outer sheath | two | polyvinyl chloride |
three | polyethylene |
Note *: the flame retardant properties are divided into three levels, namely Zra, ZrB and ZrC
Usage features
Items | Technical performance | |
Rated voltage | 0.6/1kV | |
Long term allowable working temperature of conductor | The high working temperature of conductor * * is 70 ℃, and the short circuit duration is less than 160 ℃ | |
DC resistance | Comply with gb3956 | |
Laying | When laying, the ambient temperature shall not be lower than 0 ℃, and the small bending radius shall not be less than 15 times of the outer diameter of the cable. | |
Power frequency withstand voltage test | 3.5kv/5min without breakdown | |
Flame retardant properties | It can withstand GB 12666 5 (iec332-3); the smoke concentration of low smoke, low halogen and low smoke halogen-free flame retardant cables shall meet the requirements of GB 12666.7 (iec1034). |
Nominal section and core number
Cable category | Number of cores | Nominal section |
Copper core cable | 1 * | 1.5-400 |
Aluminum core cable | 2.5-400 | |
Copper and aluminum core armored cable | 10-400 | |
Copper core cable | two | 1.5-185 |
Aluminum core cable | 2.5-185 | |
Copper and aluminum core armored cable | 4-185 | |
Copper core cable | three | 1.5-300 |
Aluminum core cable | 2.5-300 | |
Copper and aluminum core armored cable | 4-300 | |
Copper core, aluminum core armored or unarmored cable | 3+1 | 4-300 |
3+2 | ||
4+1 | ||
Copper core cable | four | 1.5-300 |
Aluminum core cable | five | 2.5-300 |
Copper and aluminum core armored cable | 4-300 |
Note *: single core armored cable can only be used in DC system. If it is used in AC system, non-magnetic material or structure reducing magnetic loss shall be adopted.