HFFP Thermocouple compensation conductor
- Tel:+86-0550-7516689
- Fax:0550-7513058
- Mail:ahhl@ahhonglin.com
Description
Details:
Expression method for model, name and specification of thermocouple compensation wire:
This product is suitable for compensating wire of S, R, B, K, e, J, t, N and EA thermocouple
Executive standard: GB / t4989-1994
Product features:
1. Rated voltage: no requirement
2. Working temperature: - 25 ~ + 200 ℃
3. Conductor: solid core or stranded gold wire
4. Insulation: PVC / PTFE
5. Sheath: PVC / PTFE / alkali free glass fiber
6. Shielding: tinned copper wire or galvanized steel wire or aluminum plastic composite belt
7. Color: Red / yellow / Blue / White / Black / Grey / Brown etc
Features / uses:
The compensating wire for thermocouple is a pair of insulated wires with the same nominal value of the thermoelectric EMF of the matched thermocouple in a certain temperature range (including normal temperature). It is used to connect the thermocouple and the measuring device to compensate the error caused by the temperature change at the junction of the thermocouple and the thermocouple. It can be divided into extended type and compensation type.
Delivery requirements:
According to the contract agreement of both parties, short delivery of no less than 10 meters is allowed. The quantity shall not exceed 10% of the total delivery length.
Model, name and matching thermocouple:
model | name | With thermocouple | Thermocouple graduation | Product model meaning |
SC or RC | Copper copper nickel 0.6 compensating conductor | Platinum Rhodium 10 platinum thermocouple | S or R | S - represents the thermoelectric characteristic tolerance, which is a precision compensation wire; P - is the compensation wire with shielding layer; G - is the general compensating wire; V-pvc material (PVC); h-means heat-resistant compensating wire; f-ptfe material; r-multi strand compensating wire; b-alkali-free glass fiber material |
KCA | Fe Cu Ni 22 compensating conductor | Ni Cr Ni Si thermocouple | K | |
NC | Fe Cu Ni 18 compensating conductor | Ni Cr Si Ni Si thermocouple | N | |
EX | Nickel chromium 10 copper nickel 45 extension type conductor | Ni Cr Cu Ni thermocouple | E | |
JX | Fe Cu Ni 45 extension conductor | Fe Cu Ni thermocouple | J | |
TX | Copper copper nickel 45 extension conductor | Copper constantan thermocouple | T |
Product specification:
Core type | Nominal core cross section (mm2) | Number of core strands | Single wire diameter of alloy wire (mm) |
Single strand core | zero point two | one | zero point five two |
Multi strand core (flexible cord) | zero point two | seven | zero point two zero |
Product structure size:
Use classification | Nominal core cross section | Nominal thickness of insulation | Nominal sheath thickness | Compensation conductor * large outer diameter (mm) | |
Single strand core | Multi strand flexible core | ||||
General use | zero point two | zero point four | zero point seven | three × four point six | three point one × four point eight |
Heat resistant | zero point two | zero point four | zero point three | two point three × four | two point four × four point two |
Reciprocating resistance at 20 ℃:
Model of compensating wire | Nominal core cross section (mm2) | ||||
zero point two | zero point five | one | one point five | two point five | |
SC or RC | zero point two five | zero point one zero | zero point zero five | zero point zero three | zero point zero two |