electromagnetic flowmeter
- Tel:+86-0550-7516689
- Fax:0550-7513058
- Mail:ahhl@ahhonglin.com
Description
summary:
The measurement principle of electromagnetic flowmeter is Faraday's law of electromagnetic induction. The main components of the sensor are: measuring tube, electrode, excitation coil, iron core and yoke shell. Electromagnetic flowmeter is mainly used to measure the volume flow of conductive liquid and slurry in closed pipeline. Including acid, alkali, salt and other strong corrosive liquid. Electromagnetic flowmeter is widely used in petrochemical, iron and steel metallurgy, water supply and drainage, water irrigation, water treatment, environmental protection sewage total control, papermaking, medicine, food and other industrial and agricultural sectors flow measurement and control; It is suitable for measuring the total amount of conductive liquid.
Product features:
1. Programmable frequency low frequency rectangular wave excitation improves the stability of flow measurement and low power loss;
2. It adopts 16 bit embedded microprocessor with high speed and high precision;
3. All digital data processing, strong anti-interference ability, reliable measurement, high precision, flow measurement range can reach 150:1;
4. Ultra low EMI switching power supply, suitable for wide range of power supply voltage variation, good anti EMC performance;
5. Chinese menu operation, easy to use, easy to operate, easy to learn and understand;
6. High definition backlight LCD display;
7. It has two-way flow measurement, two-way total cumulative function, current and frequency with two-way output function;
8. There are three integrators in the interior, which can display the positive cumulative quantity, the reverse accumulated quantity and the difference accumulated quantity;
9. With RS485 or RS232 digital communication signal output
10. With conductivity measurement function, it can judge whether the sensor is empty;
11. The constant current excitation current range is large, which can be used with different companies and different types of electromagnetic flow sensors;
12. It has the function of self inspection and self diagnosis;
13. SMD devices and surface mount (SMT) technology are used to improve the circuit reliability;
14. The internal design of the instrument has a non power down clock, which can record 16 power down times.
Main technical data:
Technical data of whole machine and sensor
Executive Standards | |||||||||
Nominal diameter | 10、15、20、25、32、40、50、65、80、100、125、150、200、250、300、350、400、500、600、700、800、900、1000、1200、1400、1600、1800、2000、2200、2400、2600、2800、3000 | ||||||||
***High velocity | 15m/s | ||||||||
Accuracy | DN10~DN600 | 5% (flow rate ≥ 1m / s); ± 3mm / S (flow rate < 1m / s) | |||||||
DN700~DN3000 | 5% (flow rate ≥ 0.8m / s); ± 4mm / S (velocity < 0.8m / s) | ||||||||
Fluid conductivity | ≥5uS/cm | ||||||||
Nominal pressure | 4.0MPa | 1.6MPa | 1.0MPa | 0.6MPa | 6.3、10MPa | ||||
DN10~DN80 | DN100~DN150 | DN200~DN1000 | DN1200~DN2000 | Special order | |||||
ambient temperature | sensor | -25℃~+60℃ | |||||||
Converter and all in one | -10℃~+60℃ | ||||||||
Lining material | Polytetrafluoroethylene, polychloroprene rubber, polyurethane, perfluoroethylene propylene (F46), screening PFA | ||||||||
***High fluid temperature | All in one | 70℃ | |||||||
Separable type | Polychloroprene rubber lining | 80℃; 120 ℃ (indicate when ordering) | |||||||
Polyurethane lining | 80℃ | ||||||||
PTFE lining | 100℃; 150 ℃ (indicate when ordering) | ||||||||
Perfluoroethylene propylene (F46) | |||||||||
Screening PFA | |||||||||
Signal electrode and grounding electrode materials | Stainless steel 0crl8nil2m02ti, Hastelloy C, Hastelloy B, titanium, tantalum, platinum / iridium alloy, stainless steel coated tungsten carbide | ||||||||
Electrode scraper mechanism | DN300~DN3000 | ||||||||
Connection flange material | carbon steel | ||||||||
Grounding flange material | Stainless steel 1Crl8Ni9Ti | ||||||||
Imported protective flange material | DN65~DN150 | Stainless steel 1Crl8Ni9Ti | |||||||
DN200~DN1600 | Carbon steel + stainless steel 1Crl8Ni9Ti | ||||||||
Enclosure protection | DN 10 ~ dn3000 separate type rubber or polyurethane lining sensor | IP65 or IP68 | |||||||
Other sensors, integrated flow meters and separate converters | IP65 | ||||||||
Spacing (split type) | The distance between transducer and sensor is generally less than 100m | ||||||||
Converter technical data
Power Supply | communication | 85~265V,45~400Hz |
direct | 11~40V | |
| lithium battery | ||
Operation key and display | Button type | All parameters can be set and selected by 4 film keys, and the converter can be programmed by PC (RS232); |
Magnetic key type | Two magnetic keys are used to select and reset the display parameters, and PC (RS232) is used to set and program the converter; 2-line LCD with wide viewing angle, wide temperature and backlight display: Line 1: magnetic key selection: display flow percentage, total forward, total reverse, total difference, alarm and flow rate. Line 2: shows the flow. | |
Internal integrator | Positive total, reverse total and difference total. | |
output signal | Unidirectional analog output | Full isolation, load ≤ 600D. (20mA); Upper limit: 0 ~ 21ma, 1mA for each gear; Lower limit: 0 ~ 21ma, 1mA for each gear; Positive and negative flow output mode programming. |
Bi directional analog output | The lower limit is 0 or 4mA, and the others are the same as unidirectional analog output. | |
Bidirectional pulse output | The two outputs correspond to forward and reverse flow respectively, with frequency of 0-800hz, upper limit of 1-800hz, and 1Hz of each gear; Square wave or selected pulse width, the upper limit of selected pulse width is 2.5s, 1ms for each gear; Passive isolation transistor switch output, can absorb 250mA current, withstand voltage 35V. | |
Two way alarm output | It can alarm (program) high / low flow, air pipe, fault state, positive and negative flow, analog over range, pulse over range, pulse small signal removal, and output polarity is optional; With isolation protection transistor switch output, can absorb 250mA current, withstand voltage 35V (not isolated from pulse output) | |
Digital communication | RS232,RS485,HART | |
Selection of lining
Lining material | main performance | ***High medium temperature | Scope of application | |
All in one | Separable type | |||
Polytetrafluoroethylene (F4) | It is a kind of plastic with stable chemical properties. It is resistant to boiling hydrochloric acid, sulfuric acid, sodium hydroxide and aqua regia. It is also resistant to concentrated alkali and various organic solvents. It is not resistant to the corrosion of chlorine trifluoride, high temperature chlorine trifluoride, high flow rate liquid fluorine, liquid oxygen and self oxygen. | 70℃ | 100 ℃ 150 ℃ (special order required) | 1. Strong corrosive media such as concentrated acid and alkali. 2. Sanitary media. |
Perfluoroethylene propylene (F46) | The wear resistance and negative pressure resistance of F4 are higher than that of F4. | ditto | ||
Polyfluoroethylene (FS) | The upper limit of applicable temperature is lower than that of polytetrafluoroethylene, but the cost is also lower. | 80℃ | ||
Polychloroprene rubber | 1. It has excellent elasticity, high breaking force and good wear resistance. 2. It is resistant to corrosion of low concentration acid, alkali and salt medium, but not to oxidation medium. | 80 ℃ 120 ℃ (special order required) | Water, sewage and slurry with weak abrasion resistance. | |
Polyurethane rubber | 1. The wear resistance is very strong. 2. Poor corrosion resistance. | 80℃ | Mineral slurry, coal slurry and mud with neutral strong abrasion | |
Selection of inlet protection flange and grounding flange (or grounding ring)
Flange type | Scope of application |
Grounding flange (or grounding ring) | Suitable for non-conductor pipes, such as plastic pipes, but not required for sensors with grounding electrodes. |
Inlet protection flange | When the medium has strong wear resistance. |
Selection of electrode
Electrode material | Corrosion resistance and wear resistance |
Stainless steel 0crl8nil2m02ti | It is suitable for industrial water, domestic water, sewage and other weakly corrosive media. It is suitable for petroleum, chemical, steel and other industrial sectors and municipal, environmental protection and other fields. |
Hastelloy B | It has good corrosion resistance to all concentrations of hydrochloric acid below boiling point, as well as non chlorinated acid, alkali and non oxidizing salt solution such as sulfuric acid, phosphoric acid, hydrofluoric acid and organic acid. |
Hastelloy C | It can resist the corrosion of non oxidizing acid, such as × ×, mixed acid, or mixed medium of chromic acid and sulfuric acid, as well as the corrosion of oxidizing salts such as FC +, Cu + or containing other oxidants, such as hypochlorite solution higher than normal temperature and seawater corrosion |
titanium | It can resist the corrosion of seawater, various chlorides and hypochlorites, oxidizing acids (including fuming sulfuric acid), organic acids and alkalis. It is not resistant to the corrosion of pure reducing acid (such as sulfuric acid and hydrochloric acid), but the corrosion is greatly reduced if the acid contains oxidants (such as × ×, FC +, Cu +). |
tantalum | It has excellent corrosion resistance and is similar to glass. In addition to hydrofluoric acid, fuming sulfuric acid and alkali, it can almost resist the corrosion of a chemical medium (including hydrochloric acid with boiling point, * * *) and sulfuric acid below 150 ℃). In the alkali Diao; Corrosion resistance. |
Platinum / titanium alloy | It is resistant to almost all chemical media, but not suitable for aqua regia and ammonium salts. |
Stainless steel coated with tungsten carbide | It is used for non corrosive and strong wear medium. |
Note: since there are many kinds of media and their corrosivity is affected by complex factors such as temperature, concentration and flow rate, this table is for reference. Users should make their own choice according to the actual situation. If necessary, the corrosion resistance test of the materials to be selected, such as coupon test, should be carried out. | |
Selection of electromagnetic flowmeter
Range confirmation
In general, the flow rate of the measured medium of the general industrial electromagnetic flowmeter should be 2-4m / s. under special circumstances, the flow rate of the medium at low speed should not be less than 0.2m/s, and the flow rate should be higher than or equal to 0.2m/s
It should be no more than 8m / s. If the medium contains solid particles, the flow rate should be less than 3m / s to prevent excessive friction between lining and electrode; For viscous fluids,
The flow rate can be greater than 2m / s. The larger flow rate is helpful to automatically eliminate the effect of sticky substances attached to the electrode, which is conducive to improving the measurement accuracy.
Under the condition that the range Q has been determined, the diameter D of the flowmeter can be determined according to the range of the above flow rate v. the value is calculated by the following formula:
Q=π*3600D ² V/4
Q: flow (M ³/ h) D: inner diameter of pipeline V: velocity (M / s)
The range Q of the electromagnetic flowmeter should be greater than the expected large flow value, while the normal flow value should be slightly greater than 50% of the full scale of the flowmeter.
Reference flow range of electromagnetic flowmeter
Diameter mm | Flow range M ³/ h | Diameter mm | Flow range M ³/ h |
| φ ten | 0.16~2.5 | φ four hundred | 250~4000 |
φ fifteen | 0.4~6 | φ five hundred | 400~6000 |
φ twenty | 0.6~12 | φ six hundred | 600~10000 |
φ twenty-five | 1.0~16 | φ seven hundred | 800~12000 |
| φ thirty-two | 1.6~25 | φ eight hundred | 1000~16000 |
φ forty | 2.5~40 | φ nine hundred | 1200~20000 |
φ fifty | 4.0~60 | φ one thousand | 1600~25000 |
φ sixty-five | 6.0~120 | φ one thousand and two hundred | 2500~30000 |
φ eighty | 10~160 | φ one thousand and four hundred | 3000~50000 |
φ one hundred | 16~250 | φ one thousand and six hundred | 3000~60000 |
| φ one hundred and twenty-five | 25~400 | φ one thousand and eight hundred | 5000~60000 |
φ one hundred and fifty | 40~600 | φ two thousand | 6000~100000 |
φ two hundred | 60~1000 | φ two thousand and two hundred | 1367.78~136778.4 |
φ two hundred and fifty | 100~1600 | φ two thousand and four hundred | 1627.78~162777.6 |
φ three hundred | 160~2500 | φ two thousand and six hundred | 1910.38~191037.6 |
φ three hundred and fifty | 200~3000 |