Description
Structural principle
Yx-160-b explosion proof electric contact pressure gauge is composed of flameproof enclosure, measuring system, electric contact group, regulating device and outlet box. The flameproof shell of the pressure gauge has good flame-proof performance. Therefore, the explosion-proof electric contact pressure gauge can withstand the explosion pressure produced by the explosive gas mixture inside the shell once it causes explosion, and can effectively prevent the heat energy generated from it from spreading smoothly, However, it can only spread out slowly along the small gap of the flameproof joint surface inside the shell. At this time, the instantaneous temperature transmitted to the outside of the shell has been reduced below the ignition point temperature of the explosive gas mixture, so it will not cause detonation propagation.
The working principle of the explosion-proof electric contact pressure gauge is based on the elastic deformation of the detecting element (spring tube in the measuring system), which drives the contact in the electric contact group to produce corresponding action (closing or breaking) through mechanical transmission, so as to make the circuit in the pressure control system connected or disconnected, so as to realize the purpose of automatic control alarm and on-site indication.
Main technical indicators
Accuracy level: 1.5
The scale range is 0-0.16; 0~0.25; 0~0.4; 0~0.6; 0~1; 0~1.6; 0~2.5; 0~4; 0~6; 0~10; 0~16; 0~25; 0~40; 0~60;- 0.1~0.06;- 0.1~0.15;- 0.1~0.3;- 0.1~0.5;- 0.1~0.9;- 0.1~1.5;- 0.1~2.4MPa
Control mode: upper and lower limit slow travel contact switch
***High working voltage: DC 220 V or AC 380 V;
Contact power: 10va
Working position: vertical installation
The operating environmental conditions are: - 10 ~ 50 ℃, relative humidity is not more than 80%, and the explosive mixture should belong to class IIB and below T4 group. The working vibration and sharp pulsation of measured medium have no influence on the reliable action of instrument contact.
Temperature effect: the indication value is not more than 0.4% / 10 ℃, and the set point is not more than 0.6% / 10 ℃ (the use temperature deviates from 20 ± 5 ℃).
Insulation strength: 50 Hz sinusoidal alternating current 2000V, lasting for one minute
Weight: 6kg
·Types and basic parameters of flameproof joint surface
Shell volume V (L) | >0.5 | |
Joint surface type | plane | Cylinder (movable part) |
Small effective length of flameproof joint surface LMM | fifteen | |
Screw through hole edge to flameproof joint surface * small effective length L1 | eight | |
Large gap or diameter difference of flameproof joint surface | zero point one five | |
Surface roughness Ra of flameproof joint surface | three point two | one point six |
Note: for examples of effective length and gap width of flameproof joint surface, please refer to structural diagram of flameproof enclosure.
·Flameproof enclosure and pressure conducting system and other parts and materials
Part name | Material brand or name | Part name | Material brand or name |
Drive case cover | ZL102 | Thin washer | L3 |
Joint | twenty | ||
axle sleeve | QAJ9-2 | Bourdon tube | 3J53 |
Observation window | organic glass |